Resolution: standard / high Figure 4.
Illustrates the limitations of setting a single threshold value to segment a mammogram
for measurement of density. (a) Aerial view of mountains in the South Island of New Zealand. The altitude of the snow
line varies so that a single value is not adequate to separate the snow-covered (dense)
from bare (fatty) regions. (b) A schematic illustration of this problem. The edge and density brightness thresholds
are denoted by the horizontal dashed lines Because of the reduction in thickness of
the breast near the periphery, the brightness of a region of dense tissue in the mammogram
(between the two vertical dashed lines) falls below the density threshold and so is
excluded from the measurement. Similarly, fatty tissue in an area of the breast that
is thicker than average can be inappropriately registered as dense tissue.
Yaffe Breast Cancer Research 2008 10:209 doi:10.1186/bcr2102 |