Breast Cancer Research

official impact factor 5.79

Review

Imaging in breast cancer: Diffuse optics in breast cancer: detecting tumors in pre-menopausal women and monitoring neoadjuvant chemotherapy

Bruce J Tromberg1*, Albert Cerussi1, Natasha Shah1, Montana Compton1, Amanda Durkin1, David Hsiang2, John Butler2 and Rita Mehta2

Author Affiliations

1 Laser Microbeam and Medical Program, Beckman Laser Institute, University of California, Irvine, CA, USA

2 Chao Family Comprehensive Cancer Center, University of California, Irvine, CA, USA

For all author emails, please log on.

Breast Cancer Research 2005, 7:279-285 doi:10.1186/bcr1358

Published: 28 November 2005

Abstract

Diffuse optical spectroscopy (DOS) and diffuse optical imaging (DOI) are non-invasive diagnostic techniques that employ near-infrared (NIR) light to quantitatively characterize the optical properties of centimeter-thick, multiple-scattering tissues. Although NIR was first applied to breast diaphanography more than 70 years ago, quantitative optical methods employing time- or frequency-domain 'photon migration' technologies have only recently been used for breast imaging. Because their performance is not limited by mammographic density, optical methods can provide new insight regarding tissue functional changes associated with the appearance, progression, and treatment of breast cancer, particularly for younger women and high-risk subjects who may not benefit from conventional imaging methods. This paper reviews the principles of diffuse optics and describes the development of broadband DOS for quantitatively measuring the optical and physiological properties of thick tissues. Clinical results are shown highlighting the sensitivity of diffuse optics to malignant breast tumors in 12 pre-menopausal subjects ranging in age from 30 to 39 years and a patient undergoing neoadjuvant chemotherapy for locally advanced breast cancer. Significant contrast was observed between normal and tumor regions of tissue for deoxy-hemoglobin (p = 0.005), oxy-hemoglobin (p = 0.002), water (p = 0.014), and lipids (p = 0.0003). Tissue hemoglobin saturation was not found to be a reliable parameter for distinguishing between tumor and normal tissues. Optical data were converted into a tissue optical index that decreased 50% within 1 week in response to neoadjuvant chemotherapy. These results suggest a potential role for diffuse optics as a bedside monitoring tool that could aid the development of new strategies for individualized patient care.